I/O Signal conditioning | Eurotherm Limited Temperature Control, Process Control, Measurement and Data Recording Solutions Thu, 04 Apr 2024 20:36:37 +0000 en-US hourly 1 https://wordpress.org/?v=6.4.2 Ultra SlimPak https://www.eurotherm.com/us/products/ancillary-equipment-us/i-o-signal-conditioning-us/ultra-slimpak/ Mon, 15 Oct 2018 08:55:20 +0000 https://eurotherm.com/product/ultra-slimpak/ DIN Rail Mount Signal Conditioners, Isolators, & Alarms

Ultra SlimPaks are high density, DIN Rail mount, setpoint limit alarm and isolating signal conditioner modules. All Ultra SlimPak modules utilise Action’s advanced, ASIC-based design for field configurable input and output flexibility.

The post Ultra SlimPak appeared first on Eurotherm Limited.

]]>
  • Field Configurable
  • Wide Ranging
  • High Density DIN Rail Mount
  • ASIC Based Design for Maximum Reliability
  • Ordering Information
    Part number Function Input Input Span (Field Configurable) Housing Width Output (Field Configurable)
    G408
    Isolator DC Volts 10mV to 100V 12.6mm DC Voltage (0-5V, 0-10V)
    DC Current 1mA to 100mA DC Current (0-1mA, 0-20mA, 4-20mA)
    G408-1001
    Isolator DC Volts 10mV to 100V 12.6mm DC Voltage (-5 to +5V, -10 to +10V)
    DC Current 1mA to 100mA
    G108
    Limit Alarm 10mV to 200V 17.5mm Alarm (Dual SPDT Relay)
    1mA to 100mA
    G418
    Isolator 3 Wire RTD Platinum: 100, 500, 1000 Ohm with 16 ranges from -200 to 600°C down to -18 to 50°C 17.5mm DC Voltage (0-5V, 0-10V)
    Copper: 10, 25, 100 Ohm with 9 ranges from -200 to 260°C down to -18 to 50°C DC Current (0-1mA, 0-20mA, 4-20mA)
    (50%adjustment in any range)
    G118
    Isolator 3 Wire RTD Platinum: 100, 500, 1000 Ohm with 16 ranges from -200 to 600°C down to -18 to 50°C 17.5mm Alarm (Dual SPDT Relay)
    Copper: 10, 25, 100 Ohm with 9 ranges from -200 to 260°C down to -18 to 50°C
    (50%adjustment in any range)
    G428
    Isolator Thermocouple Type B: 500 to 1820°C 12.6mm DC Voltage (0-5V, 0-10V)
    Type E: -150 to 1000°C DC Current (0-1mA, 0-20mA, 4-20mA)
    Type J: -200 to 750°C
    Type K: -200 to 1370°C
    Type R/S: 50 to 1760C
    Type T: -150 to 400C
    G128
    Limit Alarm Thermocouple Type B: 500 to 1820°C 17.5mm Alarm (Dual SPDT Relay)
    Type E: -150 to 1000°C
    Type J: -200 to 750°C
    Type K: -200 to 1370°C
    Type R/S: 50 to 1760C
    Type T: -150 to 400C
    G438
    Isolator Potentiometer 100 ohms to 100k ohms 12.6mm DC Voltage (0-5V, 0-10V)
    DC Current (0-1mA, 0-20mA, 4-20mA)
    G448
    Isolator Strain Gauge 0 to 200mV 17.5mm DC Voltage (0-5V, 0-10V)
    +/-5mV to +/-200mV DC Current (0-1mA, 0-20mA, 4-20mA)
    Excitation: 1-10VDC @ 120 mA
    G468
    Isolator AC Volts 50mV AC to 250VAC 12.6mm DC Voltage (0-5V, 0-10V)
    AC Current 50mA AC to 100mA AC DC Current (0-1mA, 0-20mA, 4-20mA)
    G168
    Limit Alarm AC Volts 50mV AC to 250VAC 17.5mm Alarm (Dual SPDT Relay)
    AC Current 50mA AC to 100mA AC
    G478
    Isolator Frequency 2Hz to 10kHz 12.6mm DC Voltage (0-5V, 0-10V)
    DC Current (0-1mA, 0-20mA, 4-20mA)
    WV905
    Power Supply AC Power 100 to 240VAC, 50 to 60Hz 22.5mm 24VDC @ 500mA

    The post Ultra SlimPak appeared first on Eurotherm Limited.

    ]]>
    Ultra SlimPak II https://www.eurotherm.com/us/products/ancillary-equipment-us/i-o-signal-conditioning-us/ultra-slimpak-ii/ Mon, 15 Oct 2018 08:55:20 +0000 https://eurotherm.com/product/ultra-slimpak-ii/ DIN Rail Mount Signal Conditioners, Isolators, Alarms, & Power Supplies

    The Ultra SlimPak II Series can function as traditional standalone limit alarms and isolators, or they can simultaneously be connected to your company’s intranet to monitor your signals via a standard browser when coupled with the optional WVC16 interface unit.

    The post Ultra SlimPak II appeared first on Eurotherm Limited.

    ]]>
  • Ethernet Connectivity to Most Client Software
  • Built In Web Browser with Email and Logging Capability
  • PC or Button Setup and Calibration
  • Smart Power Technology Automatically Adjusts Power
  • High Density Modules
  • Reduced Wiring with Jumpers Transferring Power from
  • Module to Module
  • Removable Connectors
  • Fast Response and High Accuracy
  • In-Process Calibration
  • Ordering Information
    Part number Function Input Input Span (Field Configurable) Housing Width Output (Field Configurable
    WV408
    Isolator DC Volts +/-150mV, +/-1.5V, +/-15V, +/-150V 12.7mm DC Voltage (0-10V)
    DC Current +/-2.5mA, +/-25mA DC Current (0-20mA, 4-20mA)
    (95%adjustment in any range)
    WV108
    Limit Alarm DC Volts +/-20mV, +/-200mV, +/-2V, +/-20V, +/-200V 17.5mm Alarm (Dual SPDT Relay)
    DC Current +/-10mA, +/-100mA
    WV418
    Isolator 2, 3 & 4 Wire RTD Platinum RTD: -200 to 600°C 17.5mm DC Voltage (0-10V)
    Copper RTD: -200 to 260°C DC Current (0-20mA, 4-20mA)
    (95%adjustment in any range) (95%adjustment in any range)
    WV118
    Limit Alarm 2 & 3 Wire RTD Platinum RTD: -200 to 600°C 17.5mm Alarm (Dual SPDT Relay)
    Copper RTD: -200 to 260°C
    (95%adjustment in any range)
    WV428
    Isolator Thermocouple Type B: 75 to 1800°C 12.7mm DC Voltage (0-10V)
    Type C: 0 to 2315°C (428 only) DC Current (0-20mA, 4-20mA)
    Type E: -200 to 1000°C (95%adjustment in any range)
    Type J: -210 to 760°C
    Type K: -200 to 1370°C
    Type N: -200 to 1300°C (428 only)
    Type R/S: 0 to 1760°C
    Type T: -200 to 390°C
    (95%adjustment in any range)
    WV128
    Limit Alarm Thermocouple Type B: 75 to 1800°C 17.5mm Alarm (Dual SPDT Relay)
    Type C: 0 to 2315°C (428 only)
    Type E: -200 to 1000°C
    Type J: -210 to 760°C
    Type K: -200 to 1370°C
    Type N: -200 to 1300°C (428 only)
    Type R/S: 0 to 1760°C
    Type T: -200 to 390°C
    (95%adjustment in any range)
    WV438
    Isolator Potentiometer 100 ohms to 100k ohms 12.7mm DC Voltage (0-10V)
    DC Current (0-20mA, 4-20mA)
    (95%adjustment in any range)
    WV448
    Isolator Strain Gauge +/-5mV to +/-200mV 17.5mm DC Voltage (0-10V)
    Excitation: 1-10VDC @ 120mA DC Current (0-20mA, 4-20mA)
    (95%adjustment in any range)
    WV468
    Isolator AC Volts 50mV AC to 250VAC 12.7mm DC Voltage (0-10V)
    AC Current 20mA AC to 100mA AC DC Current (0-20mA, 4-20mA)
    (95%adjustment in any range)
    WV168
    Limit Alarm AC Volts 50mV AC to 250VAC 17.5mm Alarm (Dual SPDT Relay)
    AC Current 20mA AC to 100mA AC
    WV478
    Isolator Frequency 2Hz to 10kHz 12.7mm DC Voltage (0-10V)
    DC Current (0-20mA, 4-20mA)
    (95%adjustment in any range)
    WV905
    Power Supply AC Power 85 to 265VAC, 50 to 60Hz 22.5mm 24VDC @ 500mA
    DC Power 120 to 300VDC
    WVC16
    Communications Interface DC Power 22.5mm Config summary/editing; diagnostics; alarm setup/
    / status; e-mail; process variable viewing; data logging

    The post Ultra SlimPak II appeared first on Eurotherm Limited.

    ]]>
    Omni Series https://www.eurotherm.com/us/products/ancillary-equipment-us/i-o-signal-conditioning-us/omni-series/ Mon, 15 Oct 2018 08:52:45 +0000 https://eurotherm.com/product/omni-series/ Omni Series Signal Conditioners

    Signal Conditioners apply across a range of requirements; amplifying or splitting signals, conditioning sensor outputs, isolating grounding problems, or adding more drive to current loops.

    The post Omni Series appeared first on Eurotherm Limited.

    ]]>
    Isolation

    A ground loop can occur if more than one ground connection is made to a single control signal. Because grounds are seldom at the same potential, an unwanted current will be generated and interfere with the control signal. Signal isolators break the ground loop current path and maintain the integrity of the measurement.

    Noise Filtering

    Isolators incorporate low pass filters that eliminate high frequency EMI/RFI and unwanted  signals from power lines, generators and motors.

    Linearisation

    Many sensors output a signal that is not linearly related to the engineering value being measured. For example, a thermocouple used to measure temperature has a nonlinear millivolt output. A thermocouple input signal isolator translates this to a standard robust linear signal such as 4 to 20 MA.

    Signal Conversion

    Industrial applications use a wide array of sensors to measure temperature, flow, length, speed etc. These signals may then need to be converted into a form usable by the instrumentation to which they are connected. Any sensor signal (thermocouple, RTD, DC voltage, DC current) can be converted to any standard process signal.

    Omni Series Products

    SL408 OmniSLIM Isolated Converter

    • Isolation and conversion of standard DC signals
    • Slimline housing of 6 mm
    • Power supply and signal isolator for 2-wire transmitter
    • Loop supply >17 V
    • DIP-switch configured

    SL408-B OmniSLIM Bi-Polar Isolated Converter

    • Conversion of voltage and current bipolar process signals to unipolar signals
    • Multiple signal ranges are selectable via DIP-switches
    • Fast response time < 7 ms and high output load stability
    • Excellent accuracy, better than 0.05 % of selected range
    • Slimline 6 mm housing

    SL500 OmniSLIM Loop Powered Isolator

    • 1 or 2 channel input loop powered isolator
    • Signal 1:1 functional range 0…23 mA
    • Low input voltage drop and fast response time
    • Excellent accuracy and high load stability
    • Slimline 6 mm housing

    SL501 OmniSLIM 2-Wire Transmitter Isolator

    • 1 or 2 channel 2-wire transmitter isolator
    • Signal 1:1 functional range 3.5…23 mA
    • Low channel voltage drop and fast response time
    • Excellent accuracy
    • Slimline 6 mm housing

    SL508-B OmniSLIM Bi-Polar Isolated Converter/Splitter

    • Conversion of voltage and current bipolar process signals to uni-/bipolar signals
    • Multiple signal ranges are selectable via DIP-switches
    • Splitter function: 1 signal in and 2 signals out
    • Excellent accuracy, better than 0.05 % of selected range and high output load stability
    • Slimline 6 mm housing

    SL418 OmniSLIM Pt100 Converter – Isolated

    • Converts process measurements from Pt100 temperature sensors to voltage or current outputs
    • Multiple pre-calibrated temperature ranges are selectable via DIP-switches
    • Excellent accuracy, better than 0.1°C or 0.05% of selected range
    • Selectable < 30 ms / 300 ms response time
    • Excellent 50/60 Hz noise suppresion
    • Slimline 6 mm housing

    SL558-T OmniSLIM Temperature Converter Loop Powered – Isolated

    • Converts process measurements from Pt100 and Thermocouples J & K temperature sensors to an isolated passive 4…20 mA current output
    • Multiple pre-calibrated temperature ranges are selectable via DIP-switches
    • Excellent accuracy, better than 0.05% of selected range
    • Selectable < 30 ms / 300 ms response time
    • Excellent 50/60 Hz noise suppresion
    • Slimline 6 mm housing

    The post Omni Series appeared first on Eurotherm Limited.

    ]]>
    Action I/Q (Loop Powered) https://www.eurotherm.com/us/products/ancillary-equipment-us/i-o-signal-conditioning-us/action-i-q-loop-powered/ Mon, 15 Oct 2018 08:50:15 +0000 https://eurotherm.com/product/action-i-q-loop-powered/ The ActionI/Q DIN rail mount package was developed to reduce the cost of signal conditioning. The two primary design considerations were to house as many channels of isolated I/O as possible and to reduce the wiring requirements in terms of the number of

    The post Action I/Q (Loop Powered) appeared first on Eurotherm Limited.

    ]]>
    The post Action I/Q (Loop Powered) appeared first on Eurotherm Limited.

    ]]>
    Action I/Q™ (AC Powered, 4-Wire) https://www.eurotherm.com/us/products/ancillary-equipment-us/i-o-signal-conditioning-us/action-i-q-ac-powered-4-wire/ Mon, 15 Oct 2018 08:50:15 +0000 https://eurotherm.com/product/action-i-q-ac-powered-4-wire/ Action I/Q™ DIN Rail Mount Signal Conditioners, Isolators, & Alarms (AC Powered, 4-Wire)

    The Action I/Q Series of signal conditioners have wide ranging field configurable inputs and outputs. These DC, RTD, T/C, potentiometer, bridge/strain gauge, AC and frequency input devices incorporate TouchCalTM technology, which simplifies calibration and allows more than 90% adjustment of zero and span.

    The post Action I/Q™ (AC Powered, 4-Wire) appeared first on Eurotherm Limited.

    ]]>
    The post Action I/Q™ (AC Powered, 4-Wire) appeared first on Eurotherm Limited.

    ]]>
    Action I/Q™ (DC Powered) https://www.eurotherm.com/us/products/ancillary-equipment-us/i-o-signal-conditioning-us/action-i-q-dc-powered/ Mon, 15 Oct 2018 08:50:15 +0000 https://eurotherm.com/product/action-i-q-dc-powered/ Action I/Q (DC Powered 2-Wire / 4-Wire)

    The Action I/Q Series of signal conditioners have wide ranging field configurable inputs and outputs. These DC, RTD, T/C, potentiometer, bridge/strain gauge, AC and frequency input devices incorporate TouchCalTM technology, which simplifies calibration and allows more than 90% adjustment of zero and span.

    The post Action I/Q™ (DC Powered) appeared first on Eurotherm Limited.

    ]]>
    The post Action I/Q™ (DC Powered) appeared first on Eurotherm Limited.

    ]]>
    ActionPak https://www.eurotherm.com/us/products/ancillary-equipment-us/i-o-signal-conditioning-us/actionpak/ Mon, 15 Oct 2018 08:50:15 +0000 https://eurotherm.com/product/actionpak/ ActionPak

    Signal Conditioners and Limit Alarms.

    The post ActionPak appeared first on Eurotherm Limited.

    ]]>
    Related Terms:

    1080, 1090, 1280, 1290, 1680, 1690, 3200, 4380, 4390, 4382, 4391, 6380, 4351, 4151, 4003, 4081, 4570, 4830, 6050, 7380, 7500, 7501, 7510, 9046, H910, H915, APS-20, M004, M008, M011, M801, MD08, 4300

    The post ActionPak appeared first on Eurotherm Limited.

    ]]>